Portable Dryers envelope Print up
Additional Markets

Additional Markets

In addition to grain and feed markets, InterSystems, the brand known as a worldwide manufacturer of bulk material handling equipment and industrial sampling systems, is found on a full range of products in support of other industries.

Sales and Service

Sales and Service

Check this area often for updated manuals, software updates and limited time offers.

Resources

Resources

Learn more about GSI products and specifications in our brochure library.

About Us

About Us

GSI supports agriculture around the globe with the most extensive global manufacturing footprint and dealer network in our industry. We bring our customers local solutions with global expertise.

Portable Dryers

Increase yields and improve profits

1112 Portable Dryer

Portable Dryers

Increase yields and improve profits

Highlights

  • Harvest your grain earlier at higher moisture levels and dry it in bins on the farm, increasing yields and improving profits.
  • Shorten wait time during drying, minimize weather risks, reduce dry matter loses, and reduce head shatter loss.
  • Single, double or triple module models available.
  • All heat or Dry/Cool operation. LP or natural gas.
  • Monitor performance and control from anywhere with GSI Connect.

GSI Connect

GSI Connect on mobile device

Remote Dryer Management

Know your dryer a little less personally this harvest

Harvest is hectic. And the last thing you need is an extra trip to the dryer. With GSI Connect, you know your dryer is doing its job. So, you can stay where you are and keep doing yours.

  1. Control from anywhere
  2. See your dryer's status, moisture, temperature
  3. Adjust set points, stop your dryer and change unload speeds
  4. Monitor your dryer's performance and get alerts to reduce runtime and maximize profit

 

Getting Started is Easy

Best of all, portable dryers are just the beginning. GSI is working to make GSI Storage and Material Handling connect-ready too. So, with GSI Connect, you can put your entire grain system in your hands.

Built to Perform

Vision Controls

Vision Controls

Vision controls offer simple operation, with an easy-to-read large color graphical touch display. Located on the dryer or remote with a few wires, these controls are design specifically for GSI grain dryers, giving you unmatched options and settings to get exactly what you need from your dryer control.

Static Moisture Sampler

Static Moisture Sampler

Improve your moisture sample accuracy with the Static Moisture Sampler. Our sampler only takes readings when the grain is static and not flowing and features debris guards to ensure a trash free, accurate sample.

Specifications

Product Lineup Overview

Series Max. Holding Capacity (bu.) Approx. Drying Capacity Configuration Optional Inverters Available Models Available in X-Stream
1100 219 - 708 420 – 1,160 BPH Single module, single fan/heater Yes (no dry cool batch) None
1200 381 - 708 680 – 1,180 BPH Single module, two fans/heaters N/A None
1200S&H 381 - 708 990 – 1,330 BPH Single module, two fans/heaters
Yes 1220HX, 1222HX, 1226HX
2300 731 - 1,304 1,460 – 2,700 BPH Two modules, three fans/heaters Yes 2320X, 2322X, 2326X
2400 1,044 - 1,340 2,010 – 2,700 BPH Two modules, four fans/heaters Yes 2420X, 2426X
3400 1,074 - 1,995 2,190 – 4,000 BPH Three modules, four fans/heaters Yes 3420X, 3422X, 3426X
3600 1,534 - 1,995 2,950 – 4,000 BPH Three modules, six fans/heaters Yes 3620X, 3626X

Click to collapse specifications for each series of dryers.

1100 Series

Configuration: Single module, single fan & heater with a single plenum. Not expandable.

Application: Small to medium sized farms using bins 50,000 bushels or less with adequate bin cooling air. Perfect as a first high speed dryer, the 1100 series delivers between 420 to 1,160 BPH All Heat drying at 5-point removal. While primarily an All Heat corn drying system, the 1100 Series dryer can also be used in Continuous Batch Dry & Cool operation full time or for specific situations – putting a dry cone in a flat bottom wet bin, or occasional soybean or wheat drying – to still be able to deliver cooled grain.

Model 1108 1112 1114 1116 1118 1120 1122 1126
Dry & Cool 25% to 15% Staged Batch 170 BPH 210 BPH 250 BPH 280 BPH 320 BPH 360 BPH 390 BPH 460 BPH
Dry & Cool 20% to 15% Staged Batch 220 BPH 270 BPH 320 BPH 370 BPH 430 BPH 480 BPH 520 BPH 610 BPH
Full Heat 30% to 15%1 190 BPH 250 BPH 300 BPH 320 BPH 380 BPH 410 BPH 460 BPH 540 BPH
Full Heat 25% to 15%1 260 BPH 340 BPH 390 BPH 440 BPH 510 BPH 560 BPH 610 BPH 720 BPH
Full Heat 20% to 15%1 420 BPH 530 BPH 610 BPH 710 BPH 820 BPH 910 BPH 990 BPH 1,160 BPH
Basic Construction 1 Module, 1 Stage 1 Module, 1 Stage 1 Module, 1 Stage 1 Module, 1 Stage 1 Module, 1 Stage 1 Module, 1 Stage 1 Module, 1 Stage 1 Module, 1 Stage
Grain Columns 14" x 8' Long 14" x 12' Long 14" x 14' Long 14" x 16' Long 14" x 18' Long 14" x 20' Long 14" x 22' Long 14" x 26' Long
Total Holding Capacity 219 BU 327 BU 381 BU 436 BU 490 BU 544 BU 599 BU 708 BU
Grain Column Holding Cap. 190 BU 282 BU 329 BU 376 BU 423 BU 470 BU 517 BU 611 BU
Top Auger (Loading) 8" Flight / 2 HP 8" Flight / 2 HP 8" Flight / 3 HP 8" Flight / 5 HP 8" Flight / 5 HP 8" Flight / 7.5 HP 8" Flight / 7.5 HP 8" Flight / 10 HP
Capacity 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH
Bottom Auger (Unloading) 8" Flight / 10" Tube - 2.5 HP 8" Flight / 10" Tube - 2.5 HP 8" Flight / 10" Tube - 3 HP 8" Flight / 10" Tube - 5 HP 8" Flight / 10" Tube - 5 HP 8" Flight / 10" Tube - 7.5 HP 8" Flight / 10" Tube - 7.5 HP 8" Flight / 10" Tube - 10 HP
Meter Roll Drive VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP
Maximum Capacity 1,125 BPH 1,680 BPH 1,960 BPH 2,240 BPH 2,520 BPH 2,800 BPH 3,080 BPH 3,640 BPH
Transport Length (Hitch to Discharge Auger) 17'2" 21'2" 23'2" 25'2" 27'2" 29'2" 31'2" 35'2"
Transport Width 8' 8' 8' 8' 8' 8' 8' 8'
Transport Height2 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9")
Approx. Transport Weight 5,200 lb. 6,300 lb. 7,000 lb. 7,500 lb. 8,000 lb. 8,700 lb. 9,500 lb. 11,000 lb.
Installed Length 15'2" 19'2" 21'2" 23'2" 25'2" 27'2" 29'2" 33'2"
Installed Width 8' 8' 8' 8' 8' 8' 8' 8'
Installed Height (Excluding Foundation Supports) 14'6" 14'6" 14'6" 14'6" 14'6" 14'6" 14'6" 14'6"
Heater (Max BTU) 4.5 Mil. btu/hr 4.5 Mil. btu/hr 5.75 Mil. btu/hr 5.75 Mil. btu/hr 6.75 Mil. btu/hr 7.5 Mil. btu/hr 8.75 Mil. btu/hr 10.25 Mil. btu/hr
Fan 1 PH 10-16 HP, 36" 10-16 HP, 36" 10-16 HP, 40" 10-16 HP, 40" N/A N/A N/A N/A
Fan 3 PH 10-16 HP, 36" 15 HP, 36" 15 HP, 40" 15 HP, 40" 20 HP, 42" 25 HP, 42" 30 HP, 42" 40 HP, 42"
Single Phase, 230 V. (Min/Max Amps)5 101/122 101/156 109/164 124/179 N/A N/A N/A N/A
Three Phase, 208 V. (Min/Max Amps)5 57/95 57/95 64/115 77/127 88/138 117/193 128/204 167/244
Three Phase, 230 V. (Min/Max Amps)5 53/83 53/88 60/108 71/120 81/130 107/178 117/188 157/228
Three Phase, 460 V. (Min/Max Amps)5 29/41 29/44 32/54 38/60 43/65 56/89 61/94 81/114
Three Phase, 575 V. (Min/Max Amps)5 25/36 25/36 28/45 33/50 36/54 46/73 50/77 67/94

1200 Series

Configuration: Single module, 2 vane axial fans & heaters each with its own plenum in a 67/33 split. Not expandable.

Application: Small to medium sized farms that require flexibility in drying options. The 1200 Series is good for corn and many other grains operating in Dry & Cool mode and good for corn or rice operating in All Heat. Its economical design gives between 400 to 730 BPH Dry & Cool and 680 to 1,160 BPH All Heat at 5-point removal. As with all Vision-equipped, multiple fan GSI dryers, the 1200 Series can be operated in any mode – All Heat, Dry & Cool, Continuous Flow or Batch – for maximum flexibility.

Model 1214 1216 1218 1220 1222 1226
Dry & Cool 25% to 15% 250 BPH 290 BPH 320 BPH 350 BPH 400 BPH 450 BPH
Dry & Cool 20% to 15% 400 BPH 470 BPH 510 BPH 560 BPH 640 BPH 730 BPH
Full Heat 30% to 15%1 330 BPH 380 BPH 410 BPH 430 BPH 480 BPH 540 BPH
Full Heat 25% to 15%1 420 BPH 480 BPH 520 BPH 590 BPH 650 BPH 730 BPH
Full Heat 20% to 15%1 680 BPH 770 BPH 840 BPH 950 BPH 1,060 BPH 1,180 BPH
Basic Construction 1 Module / 2 Stages 1 Module / 2 Stages 1 Module / 2 Stages 1 Module / 2 Stages 1 Module / 2 Stages 1 Module / 2 Stages
Grain Columns 14" x 14' Long 14" x 16' Long 14" x 18' Long 14" x 20' Long 14" x 22' Long 14" x 26' Long
Total Holding Capacity 381 BU 436 BU 490 BU 544 BU 599 BU 708 BU
Grain Column Holding Cap. 329 BU 376 BU 423 BU 470 BU 517 BU 611 BU
Top Auger (Loading) 8" 5 HP 8" 5 HP 8" 5 HP 8" 7.5 HP 8" 7.5 HP 8" 10 HP
Capacity 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH
Bottom Auger (Unloading) 8" Flight / 10" Tube - 5 HP 8" Flight / 10" Tube - 5 HP 8" Flight / 10" Tube - 5 HP 8" Flight / 10" Tube - 7.5 HP 8" Flight / 10" Tube - 7.5 HP 8" Flight / 10" Tube - 10 HP
Meter Roll Drive VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP
Maximum Capacity 1,960 BPH 2,240 BPH 2,520 BPH 2,800 BPH 3,080 BPH 3,640 BPH
Transport Length (Hitch to Discharge Auger) 23'2" 25'2" 27'2" 29'2" 31'2" 35'2"
Transport Width 8' 8' 8' 8' 8' 8'
Transport Height2 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9")
Approx. Transport Weight 7,600 lbs. 8,200 lbs. 9,000 lbs. 9,800 lbs. 10,500 lbs. 12,000 lbs.
Installed Length 21'2" 23'2" 25'2" 27'2" 29'2" 33'2"
Installed Width 8' 8' 8' 8' 8' 8'
Installed Height (Excluding Foundation Supports) 14'6" 14'6" 14'6" 14'6" 14'6" 14'6"
Top Heater (Max BTU) 1@3.5 Mil. btu/hr 1@4.5 Mil. btu/hr 1@4.5 Mil. btu/hr 1@5.5 Mil. btu/hr 1@6.75 Mil. btu/hr 1@7.5 Mil. btu/hr
Bottom Heater (Max BTU) 1@3 Mil. btu/hr 1@3 Mil. btu/hr 1@3 Mil. btu/hr 1@3.0 Mil. btu/hr 1@3.0 Mil. btu/hr 1@3.0 Mil. btu/hr
Top Fan 1 PH 1@12 HP, 36" 1@15 HP, 36" 1@15 HP, 36" 1@15 HP, 40" N/A N/A
Bottom Fan 1 PH 1@12 HP, 28" 1@10 HP, 28" 1@10 HP, 28" 1@10 HP, 28" N/A N/A 
Top Fan 3 PH 1@12 HP, 36" 1@15 HP, 36" 1@15 HP, 36" 1@15 HP, 40" 1@20 HP, 42" 1@25 HP, 42"
Bottom Fan 3 PH 1@12 HP, 28" 1@10 HP, 28" 1@10 HP, 28" 1@12 HP, 28" 1@12 HP, 28" 1@12 HP, 28"
Single Phase, 230 V. (Min/Max Amps)3 157/212 177/232 177/232 191/246 N/A N/A
Three Phase, 208 V. (Min/Max Amps)3 112/162 112/162 112/162 125/202 136/213 164/240
Three Phase, 230 V. (Min/Max Amps)3 99/148 104/153 104/153 116/187 126/197 154/225
Three Phase, 460 V. (Min/Max Amps)3 52/74 55/76 55/76 61/93 66/98 80/112
Three Phase, 575 V. (Min/Max Amps)3 48/66 49/66 49/66 54/81 57/84 68/95

1200S&H Series

Configuration: Single module, two vane axial fans fans and heaters, each with its own plenum in a 50/50 split. S-Series are upgradable with additional modules, while the H-Series is not.

S-Series Application: Small, medium or large farms with plans to expand drying capacity. As the base for a two or three stack dryer, the 1200S Series is ideal for farmers with definite plans to add a second or third module at a later date. On its own, the 1200S design – similar to the 1200H – is good for those farms that need the maximum capacity on single phase and/or primarily run All Heat or can utilize Staged Auto for Dry & Cool operation.

H-Series Application: The 1200H is primarily Staged Auto or Batch Dry & Cool for corn and many other grains and can operate with corn or rice in All Heat. Economical design that produces between 570 to 700 BPH Dry & Cool and 1,080 to 1,330 BPH All Heat at 5-point removal.

Model 1214S 1218S 1220S/1220H  1222S/1222H  1226S/1226H 
Dry & Cool 25% to 15% Staged Batch 260 BPH 350 BPH 400 BPH 430 BPH 530 BPH
Dry & Cool 20% to 15% Staged Batch 360 BPH 450 BPH 520 BPH 570 BPH 700 BPH
Dry and Cool 25% to 15% 185 BPH 240 BPH 280 BPH 300 BPH 375 BPH
Dry and Cool 20% to 15% 300 BPH 385 BPH 445 BPH 485 BPH 600 BPH
Full Heat 30% to 15%1 300 BPH 390 BPH 450 BPH 490 BPH 620 BPH
Full Heat 25% to 15%1 450 BPH 540 BPH 620 BPH 670 BPH 820 BPH
Full Heat 20% to 15%1 730 BPH 860 BPH 990 BPH 1,080 BPH 1,330 BPH
Basic Construction 1 Module / 2 Stages 1 Module / 2 Stages 1 Module / 2 Stages 1 Module / 2 Stages 1 Module / 2 Stages
Grain Columns 14" x 14' Long 14" x 18' Long 14" x 20' Long 14" x 22' Long 14" x 26' Long
Total Holding Capacity 381 BU 490 BU 544 BU 599 BU 708 BU
Grain Column Holding Cap. 329 BU 423 BU 470 BU 517 BU 611 BU
Top Auger (Loading) 5 HP 5 HP 7.5 HP 7.5 HP 10 HP
Capacity 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH
Bottom Auger (Unloading) 8" Flight / 10" Tube / 5 HP 8" Flight / 10" Tube / 5 HP 8" Flight / 10" Tube / 7.5 HP 8" Flight / 10" Tube / 7.5 HP 8" Flight / 10" Tube / 10 HP
Meter Roll Drive VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP
Maximum Capacity 1,960 BPH 2,520 BPH 2,800 BPH 3,080 BPH 3,640 BPH
Transport Length (Hitch to Discharge Auger) 23'2" 27'2" 29'2" 31'2" 35'2"
Transport Width 8' 8' 8' 8' 8'
Transport Height2 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9")
Approx. Transport Weight 9,500 lbs. 11,500 lbs. 14,500 lbs. 15,500 lbs. 18,500 lbs.
Installed Length 21'2" 25'2" 27'2" 30'2" 33'2"
Installed Width 8'8" 8'8" 8'8" / 8' 8'8" / 8' 8'8" / 8'
Installed Height (Excluding Foundation Supports) 14'6" 14'6" 14'6" 14'6" 14'6"
Heaters (Max BTU) 2@3.0 Mil.btu/hr 2@3.5 Mil.btu/hr 2@4.5 Mil.btu/hr 2@4.5 Mil.btu/hr 2@6.75 Mil.btu/hr
Fans 1 PH 2@12 HP, 28" 2@10-12 HP, 36" 2@15 HP, 36" 2@15 HP, 36" N/A
Fans 3 PH   2@12 HP, 28" 2@10-12 HP, 36" 2@15 HP, 36" 2@15 HP, 36" 2@25 HP, 40"
Single Phase, 230 V. (Min/Max Amps)3 157/212 157/212 211/266 211/266 N/A
Three Phase, 208 V. (Min/Max Amps)3 106/156 106/144 131/208 131/208 196/273
Three Phase, 230 V. (Min/Max Amps)3 99/148 99/134 121/192 121/192 183/254
Three Phase, 460 V. (Min/Max Amps)3 52/74 52/68 63/96 63/96 94/127
Three Phase, 575 V. (Min/Max Amps)3 48/66 48/66 54/81 54/81 77/104

2300 & 2400 Series

2300 Series Configuration: Two modules, three fans and heaters, one on the upper module and two on the lower module.

2400 Series Configuration: Two modules, four fans and heaters, two on the upper module and two on the lower module.

Application: Medium to large farms who want to increase grain drying capacity without increasing the footprint. Primarily continuous Dry & Cool for corn and many other grains or All Heat for corn or rice. (Note: it takes bins no larger than 50,000 bu. to cool corn dried in the All Heat mode at no more than 1,500 BPH capacity for safe cooling and storage without special management.) Economical design delivers 1,000 to 1,840 BPH Dry & Cool and 1,460 to 2,700 BPH All Heat high speed drying at 5-point removal.

Models 2314 2318 2320 2322 2326 2420 2426
Dry & Cool 25% to 15% 620 BPH 770 BPH 850 BPH 930 BPH 1,130 BPH 850 BPH 1,130 BPH
Dry & Cool 20% to 15% 1,000 BPH 1,240 BPH 1,380 BPH 1,500 BPH 1,840 BPH 1,380 BPH 1,840 BPH
Full Heat 30% to 15%1 670 BPH 830 BPH 920 BPH 1,010 BPH 1,200 BPH 920 BPH 1,200 BPH
Full Heat 25% to 15%1 900 BPH 1,120 BPH 1,250 BPH 1,360 BPH 1,670 BPH 1,250 BPH 1,670 BPH
Full Heat 20% to 15%1 1,460 BPH 1,810 BPH 2,010 BPH 2,200 BPH 2,700 BPH 2,010 BPH 2,700 BPH
Basic Construction 2 Modules/3 Stages 2 Modules/3 Stages 2 Modules/3 Stages 2 Modules/3 Stages 2 Modules/3 Stages 2 Modules/4 Stages 2 Modules/4 Stages
Grain Columns 14" x 14' Long 14" x 18' Long 14" x 20' Long 14" x 22' Long 14" x 26' Long 14" x 20' Long 14" x 26' Long
Total Holding Capacity 731 BU 940 BU 1,044 BU 1,149 BU 1,304 BU 1,044 BU 1,340 BU
Grain Column Holding Cap. 679 BU 873 BU 970 BU 1,067 BU 1,261 BU 970 BU 1,261 BU
Top Auger (Loading) 5 HP 5 HP 7.5 HP 7.5 HP 10 HP 7.5 HP 10 HP
Capacity 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH
Bottom Auger (Unloading) 8" Flight / 10" Tube - 5 HP 8" Flight / 10" Tube - 5 HP 8" Flight / 10" Tube - 7.5 HP 8" Flight / 10" Tube - 7.5 HP 8" Flight / 10" Tube - 10 HP 8" Flight / 10" Tube - 7.5 HP 8" Flight / 10" Tube - 10 HP
Meter Roll Drive VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP
Maximum Capacity 1,960 BPH 2,520 BPH 2,800 BPH 3,080 BPH 3,640 BPH 2,800 BPH 3,640 BPH
Transport Length (Hitch to Discharge Auger) 23'2" 27'2" 29'2" 31'2" 35'2" 29'2" 35'2"
Transport Width 8' 8' 8' 8' 8' 8' 8'
Transport Height2 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9")
Approx. Transport Weight (Less Transport Kit) 16,000 lbs. 19,000 lbs. 21,000 lbs. 22,500 lbs. 25,000 lbs. 23,500 lbs. 28,000 lbs.
Installed Length 23'10" 27'10" 29'10" 31'10" 35'10" 29'10" 35'10"
Installed Width 8'8" 8'8" 8'8" 8'8" 8'8" 8'8" 8'8"
Installed Height (Excluding Foundation Supports) 25'11" 25'11" 25'11" 25'11" 25'11" 25'11" 25'11"
Top Heaters (Max BTU) 1@5.5 Mil. btu/hr 1@6.75 Mil. btu/hr 1@7.5 Mil. btu/hr 1@8.75 Mil. btu/hr 1@10.25 Mil. btu/hr 2@4.5 Mil. btu/hr 2@6.75 Mil. btu/hr
Bottom Heaters (Max BTU) 2@3.0 Mil. btu/hr 2@3.5 Mil. btu/hr 2@4.5 Mil. btu/hr 2@4.5 Mil. btu/hr 2@6.75 Mil. btu/hr 2@4.5 Mil. btu/hr 2@6.75 Mil. btu/hr
Top Fans 1 PH 1@15 HP, 40" N/A N/A N/A N/A N/A N/A
Bottom Fans 1 PH 2@10-12 HP, 28" N/A N/A N/A N/A N/A N/A
Top Fans 3 PH     1@15 HP, 40" 1@20 HP, 42" 1@25 HP, 42" 1@30 HP, 42" 1@40 HP, 42" 2@15 HP, 36" 2@25 HP, 40"
Bottom Fans 3 PH     2@10-12 HP, 28" 2@10-12 HP, 36" 2@15 HP, 36" 2@15 HP, 36" 2@25 HP, 40" 2@15 HP, 36" 2@25 HP, 40"
Single Phase, 220 V. (Min/Max Amps)3 230/285 N/A N/A N/A N/A 359/421 N/A
Three Phase, 208 V. (Min/Max Amps)3 147/197 158/208 199/275 199/275 302/379 213/295 382/464
Three Phase, 230 V. (Min/Max Amps)3 137/186 135/184 183/254 183/254 281/352 197/273 313/389
Three Phase, 460 V. (Min/Max Amps)3 71/93 70/92 94/127 99/132 143/176 101/139 159/197
Three Phase, 575 V. (Min/Max Amps)3 65/82 68/86 78/105 82/109 115/142 85/117 128/160

3400 & 3600 Series

3400 Series Configuration: Three modules, four fans & heaters, one on the upper and middle module and two on the lower module.

3600 Series Configuration: Three modules, six fans & heaters, two each on all three modules.

Application: The maximum grain drying capacity in a Portable Dryer unit for large farm operations. Primarily continuous Dry & Cool for corn and many other grains or All Heat for corn or rice. (Note it takes bins no larger than 50,000 bu. to cool corn dried in the All Heat mode at no more than 1,500 BPH capacity for safe cooling and storage without special management.) Economical design delivers 840 to 2,450 BPH Dry & Cool and 1,000 to 4,000 BPH All Heat high speed drying at 5-point removal.

Model 3414 3418 3420 3422 3426 3620 3626
Dry & Cool 25% to 15% 840 BPH 1,040 BPH 1,120 BPH 1,250 BPH 1,520 BPH 1,120 BPH 1,520 BPH
Dry & Cool 20% to 15% 1,340 BPH 1,670 BPH 1,800 BPH 2,020 BPH 2,450 BPH 1,800 BPH 2,450 BPH
Full Heat 30% to 15%1 1,000 BPH 1,250 BPH 1,400 BPH 1,510 BPH 1,820 BPH 1,400 BPH 1,820 BPH
Full Heat 25% to 15%1 1,360 BPH 1,680 BPH 1,830 BPH 2,040 BPH 2,480 BPH 1,830 BPH 2,480 BPH
Full Heat 20% to 15%1 2,190 BPH 2,720 BPH 2,950 BPH6 3,300 BPH6 4,000 BPH6 2,950 BPH 4,000 BPH
Basic Construction 3 Modules/4 Stages 3 Modules/4 Stages 3 Modules/4 Stages 3 Modules/4 Stages 3 Modules/4 Stages 3 Modules/6 Stages 3 Modules/6 Stages
Grain Columns 14" x 14' Long 14" x 18' Long 14" x 20' Long 14" x 22' Long 14" x 26' Long 14" x 20' Long 14" x 26' Long
Total Holding Capacity 1,074 BU 1,381 BU 1,534 BU 1,688 BU 1,995 BU 1,534 BU 1,995 BU
Grain Column Holding Cap. 1,022 BU 1,314 BU 1,460 BU 1,606 BU 1,898 BU 1,460 BU 1,898 BU
Top Auger (Loading) 5 HP 5 HP 7.5 HP 7.5 HP 10 HP 7.5 HP 10 HP
Capacity 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH 3,800 BPH
Bottom Auger (Unloading) 8" Flight / 10" Tube - 5 HP 8" Flight / 10" Tube - 5 HP 8" Flight / 10" Tube - 7.5 HP 8" Flight / 10" Tube - 7.5 HP 8" Flight / 10" Tube - 10 HP 8" Flight/10" Tube - 7.5 HP 8" Flight/10" Tube - 10 HP
Meter Roll Drive VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP VFD, 1 HP
Maximum Capacity 1,960 BPH 2,520 BPH 2,800 BPH 3,080 BPH 3,640 BPH 2,800 BPH 3,640 BPH
Transport Length (Hitch to Discharge Auger) 23'2" 27'2" 29'2" 31'2" 35'2" 29'2" 35'2"
Transport Width 8' 8' 8' 8' 8' 8' 8'
Transport Height2 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9") 13'5" (11'9")
Approx. Transport Weight (Less Transport Kit) 23,000 lbs. 26,500 lbs. 29,500 lbs. 30,500 lbs. 35,000 lbs. 30,170 lbs. 38,750 lbs.
Installed Length 23'10" 27'10" 29'10" 31'10" 35'10" 29'10" 35'10"
Installed Width 8'8" 8'8" 8'8" 8'8" 8'8" 8'8" 8'8"
Installed Height (Excluding Foundation Supports) 37'3" 37'3" 37'3" 37'3" 37'3" 37'3" 37'3"
Top Heaters (Max BTU) 2@5.5 Mil. btu/hr 2@6.75 Mil. btu/hr 2@7.5 Mil. btu/hr 2@8.75 Mil. btu/hr 2@10.25 Mil. btu/hr 3@4.5 Mil. btu/hr 3@6.75 Mil. btu/hr
Bottom Heaters (Max BTU) 2@3 Mil. btu/hr 2@3.5 Mil. btu/hr 2@4.5 Mil. btu/hr 2@4.5 Mil. btu/hr 2@6.75 Mil. btu/hr 3@4.5 Mil. btu/hr 3@6.75 Mil. btu/hr
Top Fans 1 PH 2@15 HP, 40" N/A N/A N/A N/A N/A N/A
Bottom Fans 1 PH 2@12 HP, 28" N/A N/A N/A N/A N/A N/A
Top Fans 3 PH 2@15 HP, 40" 2@20 HP, 42" 2@25 HP, 42" 2@30 HP, 42" 2@40 HP, 42" 3@15 HP, 36" 3@25 HP, 40"
Bottom Fans 3 PH 2@12 HP, 28" 2@10-12 HP, 36" 2@15 HP, 36" 2@15 HP, 36" 2@25 HP, 40" 3@15 HP, 36" 3@25 HP, 40"
Single Phase, 230 V. (Min/Max Amps)3 303/358 N/A N/A N/A N/A N/A N/A
Three Phase, 208 V. (Min/Max Amps)3 188/238 210/260 266/343 266/343 300/377 295/377 539/620
Three Phase, 230 V. (Min/Max Amps)3 175/224 183/232 245/316 245/316 279/350 273/349 441/517
Three Phase, 460 V. (Min/Max Amps)3 90/112 94/116 125/158 135/168 192/225 139/177 223/261
Three Phase, 575 V. (Min/Max Amps)3 81/98 88/106 103/130 111/138 154/181 117/149 179/211

X-Stream Series

Configuration: Various. X-Stream is an optional rearrangement of the fans on various dryers (1200H, 1200S, 2300, 2400, 3400, or 3600 Series).

Application: Any size farm that wants to optimize grain drying abilities by drying grain more evenly. Adding the X-Stream Series will even out the heat delivery from front to back of the dryer, improving quality and efficiency. These dryers maintain all the features, benefits and best use criteria of the parent series.

Models 1220SX & 1220HX 1222SX & 1222HX 1226SX & 1226HX 2320X 2322X 2326X 2420X 2426X 3420X 3422X 3426X 3620X 3626X
Modules 1 1 1 2 2 2 2 2 3 3 3 3 3
Fans 2 2 2 3 3 3 4 4 4 4 4 6 6
Phase 1 or 3 1 or 3 3 3 3 3 1 or 3 3 3 3 3 1 or 3 3
Voltage ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL
Fuel LP or NG LP or NG LP or NG LP or NG LP or NG LP or NG LP or NG LP or NG LP or NG LP or NG LP or NG LP or NG LP or NG
Weight (lbs.) 14,500 15,500 18,500 21,000 22,500 25,000 24,100 28,600 29,500 30,500 35,000 31,000 39,600
Full Heat (BPH) 10 pt.  25-15% 615 670 820 1,245 1,355 1,670 1,250 1,670 1,825 2,040 2,475 1,830 2,480
Full Heat (BPH) 5 pt.  20-15% 990 1,080 1,330 2,010 2,195 2,700 2,010 2,700 2,9506 3,3006 4,0006 2,9506 4,0006
Dry & Cool (BPH) 10 pt.  25-15% 280 300 375 850 930 1,130 850 1,130 1,120 1,250 1,520 1,120 1,520
Dry & Cool (BPH) 5 pt.  20-15% 445 485 600 1,375 1,500 1,835 1,380 1,840 1,800 2,015 2,445 1,800 2,020

Drying capacities listed are wet bushels, for mature unfrozen #2 yellow shelled dent corn at listed moisture content and are estimates based on drying principles, field results and computer simulation. Variance may occur due to grain’s physiological factors (kernel size, chemical composition, variety, maturity), excessive fines, adverse weather conditions, etc.

1 - Grain discharged hot from the dryer will result in a final moisture content of 15% after cooling in the bin.

2 - Shortest possible height in ( ).

3 - Electric Load (Fan, Load Auger, Unload Auger)
Minimum: Fan(s) & Dryer Load & Unload motor name plate amperages + 5 for control & VFD load.
Maximum: Fan(s) & Dryer Load & Unload & largest auxiliary motor name plate amperages + 5 for control & VFD load.

4 - Small Grain Screen Perforations (O.055”) are available for canola and other small grains. There will be an approximate 20% reduction in capacity on corn and other large grains.

5 - Single to three phase converters can be used.

6 - Limited by Meter Roll maximum capacity.

† - S-Series dryers are upgradable with additional modules, while the H-Series is not.